How Many Questions Of NS0-592 Question

Want to know Testking NS0-592 Exam practice test features? Want to lear more about Network-Appliance NetApp Certified Support Engineer - ONTAP Specialist certification experience? Study Guaranteed Network-Appliance NS0-592 answers to Updated NS0-592 questions at Testking. Gat a success with an absolute guarantee to pass Network-Appliance NS0-592 (NetApp Certified Support Engineer - ONTAP Specialist) test on your first attempt.

Online Network-Appliance NS0-592 free dumps demo Below:

NEW QUESTION 1
Click the exhibit button.
NS0-592 dumps exhibit
You have just cabled a new shelf to a FAS8200. Running the system node run -node * sysconfig - a command indicates that multipath HA is configured. However, after running Config Advisor, you receive an error that your cabling is incorrect.
As indicated in the exhibit, which two actions will correct the cabling? (Choose two.)

  • A. Move the 0b SAS connection on the bottom controller to 0d on the bottom controller.
  • B. Move the 0b SAS connection on the top controller to 0d on the top controller.
  • C. Move the 0b SAS connection on the top controller to 0d on the bottom controller.
  • D. Move the 0b SAS connection on the bottom controller to 0d on the top controller.

Answer: AB

NEW QUESTION 2
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?

  • A. Use the storage pool create command.
  • B. Use the volume create command.
  • C. Use the Deploy utility to provision the FlexGroup volume.
  • D. Use the volume size command.

Answer: A

NEW QUESTION 3
Your customer added a new DS2246 shelf to an existing stack on their FAS8060A system. The customer then noticed that the new shelf’s disks appear with the shelf serial number instead of the shelf ID in the sysconfig -r command output.
What is the reason for this problem?

  • A. The SAS is cabled incorrectly.
  • B. There is failed IOM module in the new shelf.
  • C. The ACP is cabled incorrectly.
  • D. The new shelf has the same ID as another shelf.

Answer: A

NEW QUESTION 4
A customer reports that a takeover has been disabled on an HA pair. What would be a cause for this to happen?

  • A. The HA interconnect is not functioning properly.
  • B. There is a disk running too hot.
  • C. The interface for the hardware assist has become unavailable.
  • D. The cluster network is not functioning properly.

Answer: A

NEW QUESTION 5
Click the exhibit button.
NS0-592 dumps exhibit
Your customer added a new DS4246 shelf to their FAS system. They created an aggregate on the new shelf. Two weeks later, they log in to Active IQ and discover the Medium Impact error shown below.
“Both SAS connections from one controller go to the same shelf.” Referring to the exhibit, which statement is correct?

  • A. You are unable to obtain a “Cable Visualization” overview from Active IQ.
  • B. A faulty cable is causing the problem.
  • C. A faulty IOM is causing the problem.
  • D. You can correct this problem without downtime on the FAS system.

Answer: D

NEW QUESTION 6
Click the exhibit button.
NS0-592 dumps exhibit
You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)

  • A. storage bridges BrB1
  • B. FC switch SwA1
  • C. FC switch SwB1
  • D. FC switch SwA2
  • E. ISL cables

Answer: BCE

NEW QUESTION 7
Click the exhibit button.
NS0-592 dumps exhibit
A customer notifies you that Active IQ is showing a warning that a broadcast domain in their environment has been configured with ports from multiple VLANs.
Referring to the exhibit, which two statements are correct? (Choose two.)

  • A. You should move the e0M ports to a Broadcast Domain that is dedicated to only management traffic.
  • B. A VLAN tag cannot be assigned to the e0M port, so the configuration is acceptable.
  • C. You should configure e0M so that is tagged on VLAN 40.
  • D. You should change the LIF service policy to net-intercluster to prevent the LIFs from failing over to the e0M ports.

Answer: CD

NEW QUESTION 8
Two weeks ago, your customer experienced a data outage, which caused their MCC to switch over. When the power was restored, they found that 14 disks over three RAID groups had failed, which caused two data aggregates to lose their mirror plexes.
In this situation, before you perform a switchback, which three actions should be taken? (Choose three.)

  • A. Delete the failed plexes.
  • B. Initiate the aggregate healing phases.
  • C. Adjust bridge configuration for the replaced disks.
  • D. Mirror the unmirrored aggregates
  • E. Assign all disks on the remote site to the surviving nodes.

Answer: BCD

NEW QUESTION 9
Click the exhibit button.
NS0-592 dumps exhibit
A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.
Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

  • A. Review the LIF configuration on the cluster.
  • B. Review the driver version on the server.
  • C. Review that the host side FC link ports are enabled.
  • D. Review the igroup configuration on the cluster.

Answer: AB

NEW QUESTION 10
You migrated from a FAS3250 system to a new A200 system. After the migration, you notice that data compaction fails to be enabled on the migrated volumes.
In this scenario, which statement is correct?

  • A. You need to schedule background deduplication on all volumes.
  • B. You need a license to have full efficiency on AFF systems.
  • C. Data compaction is not supported on the A200 system.
  • D. The volumes are thick-provisioned.

Answer: D

NEW QUESTION 11
After you replaced the motherboard, the node stopped in the “waiting for the cluster application to come
online” state.
Which two actions should you perform to troubleshoot this problem? (Choose two.)

  • A. Check the status of the HA with the interconnect-up field of storage failover show command.
  • B. Verify the setting of the cluster interconnect switch.
  • C. Verify that the physical links on the cluster ports are up.
  • D. Check the status of the cluster with the cluster ring show command.

Answer: AD

NEW QUESTION 12
Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.
In this scenario, what is the reason for the behavior?

  • A. The volume move command uses the HA iWarp interconnect, not the client access switches.
  • B. The volume move command uses copy offload protocol, so it does not show up when monitored.
  • C. The volume move command uses the intercluster LIFs, not the data LIFs.
  • D. The volume move command uses the cluster interconnect switches, not the client access switches.

Answer: B

NEW QUESTION 13
Click the exhibit button.
NS0-592 dumps exhibit
A customer reports that their system recently began logging an error. Referring to the exhibit, which two statements are correct? (Choose two.)

  • A. The bcomd application is responsible for monitoring the observed behavior.
  • B. A user is attempting to restart the ntpd daemon.
  • C. The spmd application failed to restart the ntpd daemon.
  • D. The ntpd daemon is responsible for time services.

Answer: BD

NEW QUESTION 14
Click the exhibit button.
NS0-592 dumps exhibit
A volume move operation has been initiated to move a volume named MirrScr from one aggregate to another. The operation failed with the error that is shown in the exhibit.
In this scenario, which statement is correct?

  • A. Manually trigger the cutover process in order to restart the job.
  • B. The volume move cannot be completed at this time because of high use in this node.
  • C. There are too many snapshots on the source volume.
  • D. Cancel and restart the volume move operation.

Answer: A

NEW QUESTION 15
You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.
When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day. You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid.
resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.
You have four separate ISLs between your data centers using Brocade 6510 switches. Hardware problems are not an issue.
Which two actions should you take to prevent this problem in the future? (Choose two.)

  • A. Update to at least ONTAP 9.4 software.
  • B. Restart the resynchronizations after modifying storage raid-options modify raid.resync.num_concurrent_ios_per_rg command.
  • C. Avoid changes on your aggregates during the maintenance window.
  • D. Take the corresponding plexes offline before maintenance to avoid a base-level synchronization.

Answer: AB

NEW QUESTION 16
Your customer states that the storage efficiency on their FAS 8200 is far below what they had expected for a VMware NFS datastore. They enabled deduplication three days ago. The job ran every night for only 10-20 minutes, and the space savings now is less than 5%.
What is causing the space savings to be so low?

  • A. They have enabled aggregate-level inline data compaction, so the savings are at the aggregate level.
  • B. They have enabled aggregate-level inline deduplication, so the savings are at the aggregate level.
  • C. They have not enabled volume-level compression.
  • D. They have not run a baseline deduplication to scan old data.

Answer: C

NEW QUESTION 17
......

P.S. Surepassexam now are offering 100% pass ensure NS0-592 dumps! All NS0-592 exam questions have been updated with correct answers: https://www.surepassexam.com/NS0-592-exam-dumps.html (65 New Questions)