Exact 3v0-624 Questions 2021

Your success in VMware 3v0-624 is our sole target and we develop all our 3v0-624 braindumps in a way that facilitates the attainment of this target. Not only is our 3v0-624 study material the best you can find, it is also the most detailed and the most updated. 3v0-624 Practice Exams for VMware VMware Other Exam 3v0-624 are written to the highest standards of technical accuracy.

VMware 3v0-624 Free Dumps Questions Online, Read and Test Now.

NEW QUESTION 1
A validation plan is used to do which of the following? (Select all that apply.)

  • A. Verify the design
  • B. Verify that the system is functional
  • C. Verify that the system meets requirements
  • D. Meet current best practices

Answer: ABC

NEW QUESTION 2
A company has requested assistance with a new cross-site failover design between two sites which will support business-critical applications. Latency between the sites is less than 5ms round-trip.
The company requires:
• application must be restarted quickly in the event of a total site failure
• allow for planned migration during maintenance
• applications must be kept online even when migrated due to planned maintenance
Drag each statement to its correct concept
3V0-624 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
3V0-624 dumps exhibit

NEW QUESTION 3
A solution architect has been tasked with designing a new environment that meets the needs of a growing company, and has obtained this information:
• The current capacity will be exhausted in 180 days, and the new infrastructure must be deployed and in production prior to that.
• The new servers have a 90-day delivery time.
• A data center for disaster recovery has been selected, and it is 20 miles away and connected by MPLS.
• The security team will continue to utilize its current investments and VM Encryption for the new environment.
• The backup team currently uses Data Domain, and reports show an 8:1 compression and deduplication ratio for backups.
Based on the information obtained, which two statements are risks for the new design? (Choose two.)

  • A. MPLS will be used to connect the two data centers.
  • B. The Change Advisory Board will approve all changes.
  • C. Current back up space will not be sufficient if using VM Encryption.
  • D. The current firewalls will support the additional workloads.

Answer: AB

NEW QUESTION 4
A company is implementing a new cluster to support its end user desktop workloads.
• The workload is required to support 200 virtual machines.
• Each end-user desktop is configured with two vCPUs, 8GB of RAM, and 40GB of thick-provisioned disk space.
• The architect has expressed concerns that virtual machine swap files will till the 8.5TB datastore available to the cluster.
Which two strategies would address the architect's concern? (Choose two.)

  • A. Configure an additional datastore for snapshot storage
  • B. Configure an additional datastore for vswap file storage
  • C. Configure each virtual machine with a 4GB memory reservation.
  • D. Configure each virtual machine with a 8GB memory reservation.

Answer: BD

NEW QUESTION 5
You have been tasked with creating a vSphere 6.5 data center design for an organization. The organization has identified a number of challenges that occur within their current infrastructure that they would like addressed in the design. For each challenge, determine the vSphere technologies that could be used in the design.
Match each Challenge on the left by dragging the red Challenge buttons (C1-C4) over the appropriate Technology.
3V0-624 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
3V0-624 dumps exhibit

NEW QUESTION 6
View the exhibit.
3V0-624 dumps exhibit
Referring to the exhibit, which appliance or device belongs in the square with the question mark?

  • A. Firewall Appliance
  • B. Load Balance
  • C. Platform Services Controller
  • D. vCenter Server Appliance

Answer: A

NEW QUESTION 7
Customer Information
The Customer labtown is looking to purchase a new storage system and has hired you to create a logical design. Labtown requires no single points of failure when it comes to the fabric connecting the storage. Labtown has already decided that the new storage system will be using fibre to re-use as much of the previous hardware as possible to increase ROI. Labotwn would also like a tiered disk system broken into three categories with the database sitting in the fastest tier, the two web servers sitting in the medium tier, and the file server sitting in the slowest tier.
Create a logical design for Labtowns new Storage System Requirements
- Create a tiered storage system for Labtown - No single points of failure - Insure storage performance SLA's are met with the four line of business VM's
Instructions
- Place VM's on the bottom of the page and connect them with the connector to the storage LUN they will belong to.
- Connect the stroage LUN with the service processor with the connector
- Connect the storage processors to the SAN switch
- Place HBA's just below the host, as long as they are close to the host points will be scored
- Connect HBA's to SAN switches with either the Fixed, MRU, or RR Connector to dictate the PSP Policy for storage on the ESXi host.

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
Check below for answer solution
C:WORKCert Paper ExamsVMware3V0-622SIm9Aph.jpg
3V0-624 dumps exhibit

NEW QUESTION 8
A solution architect has been tasked with designing a new environment that meets the needs of a growing company, and has obtained this information:
• The current capacity will be exhausted in 180 days, and the new infrastructure must be deployed and in production prior to that.
• The new severs have a 90-day delivery time.
• A data center for disaster recovery has been selected, and it is 20 miles way and connected by MPLS.
• The security team will continue to utilize its current investments and VM Encryption for the new environment.
• The backup team currently uses Data Domain, and reports show an 8.1 compression and deduplication ratio for backups.
Based on the information obtained, which two statements are assumptions for the new design? (Choose two.)

  • A. MPLS will be used to connect the two data centers.
  • B. There is 180 days left of current capacity.
  • C. Data Domain will get an 8:1 compression and deduplication ratio with the new workloads.
  • D. A disaster will NOT affect both data centers.

Answer: BD

NEW QUESTION 9
The system administrator team is planning to upgrade its vCenter Server 5.5 environments to version 6.5.
• Each vCenter 5.5 is pointing to a Single Sign On (SSO) server that has a dedicated virtual machine.
• The SSO servers are currently in independent SSO domains.
• During the upgrade process, the administrators would like to combine their two SSO domains into a single one.
View the exhibit.
3V0-624 dumps exhibit
Referring to the exhibit, which upgrade scenario would accomplish this?

  • A. 1. Upgrade the Denver SSO server to a 6.5 PSC.2. Upgrade the Denver vCenter Server 5.5 to version 6.5.3. Use the migration utility to upgrade the New York vCenter Server to 6.5.4. Choose to join it to the Denver PSC.
  • B. 1. Upgrade the Denver SSO server to a 6.5 PSC.2. Use the migration utility to upgrade the New York SSO server.3. Choose to join the existing SSO domain during the second upgrade.4. Upgrade both of the vCenter Servers to 6.5.
  • C. 1. Upgrade both of the SSO servers to 6.5 PSCs.2. Upgrade both of the vCenter Servers to 6.5.3. Install a new 6.5 PSC in the same SSO domain as the Denver 6.5 PSC.4. Repoint the New York vCenter Server to the newly-installed PSC.
  • D. 1. Install a new New York SSO 5.5 server in the same SSO domain as the Denver SSO server.2. Repoint the New York vCenter Server to the newly-installed SSO server.3. Upgrade both SSO servers to 6.5 PSCs.4. Upgrade both vCenter Servers to 6.5.

Answer: D

NEW QUESTION 10
A solution architect has been tasked with designing a new environment for a company's growing needs, and has obtained this information:
• Uptime is critical during regular business hours when 95% of the transactions occur. Application uptime must be 99.9% during those hours.
• In a true Disaster, the business can withstand a day of data loss and half a day of downtime.
• The company is one year into a 5-year contact with the co-lo data center.
• The building that is currently occupied no hanger has any floor space available, but the company has 3 empty racks of space. The co-lo can provide up to 11KVA of power per rack.
• There are current contacts with Dell to provide servers and with Cisco to provide the network components.
• The network team has standardized on an end-to-end 10Gb network.
Based on this information, what are two requirements for the new design? (Choose two.)

  • A. RTO of 24 hours.
  • B. RTO of 12 hours.
  • C. The application must be available 99.9% during business hours.
  • D. 11KVA of power is available per rack.

Answer: BC

NEW QUESTION 11
A company is in the process of deploying a modern video-streaming application.
• The application is able to scale (expand and collapse) its steaming nodes in the form of CentOS 7.x 64bit virtual machines, based on demand.
• This IO-Intensive application has a high CPU demand and generates a significant number of disk operations (IOPS).
• To host the application, the company decided to implement a brand-new VMware cluster with vSphere 6.5
• The company would like a significant reduction in CPU utilization as well as a possible increase in throughput.
Which virtual disk adapter should be recommended for the company's physical design?

  • A. LSI Logic Parallel
  • B. VMware Paravirtual
  • C. BusLogic Parallel
  • D. LSI Logic SAS

Answer: B

NEW QUESTION 12
Which of the following needs to be considered when determining the amount and size of thehosts required for a virtual design?

  • A. Aggregate CPU and memory requirements
  • B. Future growth
  • C. Number of vCPUs to be hosted per box
  • D. All of the above

Answer: D

NEW QUESTION 13
A customer wants to make its data available with a RPO of 10 minutes. Replication to the second data center will be done using the network.
Which type of storage configuration should be used?

  • A. NFS datastore on ESXi 6.0 with vSphere replication appliance 6.0
  • B. VMFS datastore on ESXi 6.0 with vSphere replication appliance 6.5
  • C. vSAN datastore on ESXi 6.0 with vSphere replication appliance 6.5
  • D. VMFS datastore on ESXi 6.0 with vSphere replication appliance 6.0

Answer: B

NEW QUESTION 14
A virtualization administrator has been tasked with migrating several business applications from physical to virtual. The administrator must also migrate the virtual machines from VMware Workstation to vSphere 6.5, using vCenter Converter Standalone 6.1.
In this scenario, when two source types are supported? (Choose two.)

  • A. powered-off Windows Server 2008 physical machine
  • B. powered-on Windows Server 2000 Workstation virtual machine
  • C. powered-off Windows Server 2008 Workstation virtual machine
  • D. powered-on Windows Server 2008 physical machine

Answer: CD

NEW QUESTION 15
A customer has storage arrays from two different storage vendors at two different sites. The customer warts to restore operations at the secondary site in the event of a disaster.
Which VMware technology must be used to meet this requirement?

  • A. vSphere replication
  • B. vSphere Data Protection
  • C. array-based replication
  • D. vSphere Fault Tolerance

Answer: A

NEW QUESTION 16
After the vSAN iSCSI Target service is enabled, which statement about iSCSI networks is true?

  • A. A separate VMkernel interface may be configured per target.
  • B. A single VMkernel interface must be selected for all iSCSI targets.
  • C. The vSAN iSCSI Target service always uses all Management VMkernel interfaces.
  • D. The vSAN iSCSI Target service always uses the vMotion network.

Answer: A

NEW QUESTION 17
A company's CTO is very concerned about web server outages that are caused by server hardware failures. Which feature can protect the web server virtual machine from this kind of outage?

  • A. vCenter High Availability
  • B. Proactive High Availably
  • C. High Availability Orchestrated Restart
  • D. High Availability Admission Control

Answer: B

Explanation:
http://www.vmwarearena.com/vsphere-6-5-high-availability-new-features-proactive-ha/vSphere 6.5 High Availability (HA) now also detect the hardware conditions of the ESXi host and allow you to evacuate the Virtual machines before the hardware issues cause an outage to Virtual machines with the help of Proactive HA.

NEW QUESTION 18
You have been tasked with creating a vSphere 6.5 design for an organization. The customer wants to ensure isolation in the network but does not know when to incorporate physical networks, VLANs and PVLANs.
Evaluate the design requirement and determine the isolation method to satisfy the design.
Match each Design Requirement on the left by dragging the red Requirement buttons (R1-R5) over the text of the appropriate Isolation Method.
NOTE: Multiple Design Requirements may fit each Isolation Method.
3V0-624 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
3V0-624 dumps exhibit

NEW QUESTION 19
You have been provided with a list of requirements for a vSphere Design. For each requirement, categorize the requirement as a component of the conceptual, logical, or physical design.
Drag a requirement button (R1-R8) over to the green space provided beside the corresponding Design Phase.
3V0-624 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
3V0-624 dumps exhibit

NEW QUESTION 20
A leading steel manufacturer relies on SAP for purchase, sales, add invoice processing.
• It is planning to virtualize its severs to reduce CAPEX and OPEX.
• However, its CIO is concerned about the availability, performance, manageability, recoverability, and security for the SAP database and ERP instance.
Match the business requirement with the appropriate design concept.
3V0-624 dumps exhibit

  • A. Mastered
  • B. Not Mastered

Answer: A

Explanation:
Manageability --> The App must support clustering...Performance --> The App must generate 200...Recoverability --> The App must be restored in 30...Security --> The App data must be encrypted...Availability --> The App must scale within 2h..

NEW QUESTION 21
......

Recommend!! Get the Full 3v0-624 dumps in VCE and PDF From Passcertsure, Welcome to Download: https://www.passcertsure.com/3v0-624-test/ (New 123 Q&As Version)