A Review Of Simulation 700-905 Testing Material

Want to know Actualtests 700-905 Exam practice test features? Want to lear more about Cisco Cisco HyperFlex for Systems Engineers certification experience? Study Realistic Cisco 700-905 answers to Rebirth 700-905 questions at Actualtests. Gat a success with an absolute guarantee to pass Cisco 700-905 (Cisco HyperFlex for Systems Engineers) test on your first attempt.

Online Cisco 700-905 free dumps demo Below:

NEW QUESTION 1
HyperFlex compute nodes contribute what percentage of the overall disk storage capacity?

  • A. 5%
  • B. 20%
  • C. 0%
  • D. 10%

Answer: C

Explanation:
700-905 dumps exhibit

NEW QUESTION 2
With which three components must every HyperFlex cluster be equipped with in regard to disks? (Choose three.)

  • A. NVMe drives
  • B. there are no specific requirements
  • C. same type of cache drives
  • D. same type and size of capacity of drives
  • E. same number of capacity drives
  • F. SAS drives

Answer: CDE

Explanation:
700-905 dumps exhibit

NEW QUESTION 3
When local writing or reading is performed, the lOVisor intercepts the read/write requests and forwards them to CVMs across the cluster This action allows non-local CVMs to be aware of the input/output requests so that they can perform the appropriate input/output action lOVisor provides which two additional functionalities? (Choose two.)

  • A. provides redundancy when local CVM fails, offloading data processing to another CVM in the cluster
  • B. when an lOVisor fails, the CVM remains active and functional, which enables uninterrupted operation of the system by forwarding 10 to another available lOVisor In the HyperFlex cluster
  • C. enables asynchronous replication of data across individual HyperFlex nodes with sub-second re-convergence
  • D. integration point for deployment of cloud-based SaaS offerings from eco-system partners
  • E. intercepts local virtual machines' reads and writes and distributes them across the network eliminating hotspots

Answer: AE

Explanation:
700-905 dumps exhibit

NEW QUESTION 4
Refer to the exhibit.
700-905 dumps exhibit
Which VIC model supports two wire connectivity to each Fabric Interconnect?

  • A. VIC 1227
  • B. VIC 1557
  • C. VIC 1387
  • D. VIC 1457

Answer: C

Explanation:
700-905 dumps exhibit

NEW QUESTION 5
Which three additional management tools are included in HXDP to configure HyperFlex clusters? (Choose three.)

  • A. UCS Manager
  • B. Storage CLI
  • C. Data Center Network Manager
  • D. Cisco IMC 13
  • E. REST API
  • F. HyperFlex Connect

Answer: BEF

Explanation:
700-905 dumps exhibit

NEW QUESTION 6
Which Cisco UCS Server running HXDP supports the largest storage pool?

  • A. UCS B200
  • B. HX220
  • C. HX 240
  • D. UCS B480

Answer: C

Explanation:
700-905 dumps exhibit

NEW QUESTION 7
Which two results are expected when you replace a node or expand a cluster? (Choose two.)

  • A. Distributed pooled data is migrated off nodes to master data store.
  • B. Affected node is marked as unhealthy and placed into standby mode
  • C. vSphere DRS migrates the virtual machines to the new node to balance the load
  • D. On node replace, the self-healing must finish for the cluster to be healthy
  • E. The cluster profile is updated and RAID takes care of rebalancing the load.

Answer: CD

Explanation:
700-905 dumps exhibit

NEW QUESTION 8
Which three advantages of using the M5 generation of HyperFlex servers over the M4 generation are valid? (Choose three )

  • A. Support for Cisco VICs
  • B. Multiple GPUs
  • C. M.2 SATA drive support for faster disk I/O
  • D. DDR3 memory
  • E. Microsoft Hyper-V support
  • F. NVMe support

Answer: CEF

Explanation:
700-905 dumps exhibit

NEW QUESTION 9
In all HX server types, where are capacity drives installed?

  • A. side
  • B. top
  • C. back
  • D. front

Answer: D

Explanation:
700-905 dumps exhibit

NEW QUESTION 10
Which two features enable RAID cards striping as well as mirroring and parity? (Choose two.)

  • A. Integration with Cisco Intersight for a cloud-based storage management solution.
  • B. No load on the system resources, drives seem as one drive to the operating system
  • C. On RAID card failure, the RAID onboard concurrent cache assists rebuild cache.
  • D. Hot replacement of drives available, depending on configuration
  • E. Distributed drives across disparate systems can be in RAID together.

Answer: BD

Explanation:
700-905 dumps exhibit

NEW QUESTION 11
How many separate VLANs must each HyperFlex node be configured with running ESXi?

  • A. 1
  • B. 2
  • C. 3
  • D. 4

Answer: D

Explanation:
700-905 dumps exhibit

NEW QUESTION 12
How many memory channels does the Cisco UCS M5 server support per CPU?

  • A. 1
  • B. 2
  • C. 6
  • D. 8

Answer: C

NEW QUESTION 13
Which three configurations for read caching in Cisco HyperFlex are valid? (Choose three.)

  • A. Battery-Initiated Read-back (default): Only read data and most commonly used data are deposited in the Level 4 read-back cache
  • B. Write-back (default): Only write information and most commonly used information are deposited in the cache
  • C. Write-through (install option for VDI): Only most commonly used data is cached: optimizing VDI performance
  • D. No caching (SSD): With all-flash nodes; because there is little difference in read speeds between SSDs
  • E. Level 4 cached (SSD): With semi-flash nodes; there is a large difference in read speeds between SSDs
  • F. Write-first (default for VDI): Infrequently used data is cached: freeing system resources for VDI performance

Answer: BCD

Explanation:
700-905 dumps exhibit

NEW QUESTION 14
Which two ways does Cisco HyperFlex upgrade the traditional RAID? (Choose two.)

  • A. HyperFlex enables stretched RAID arrays spanning multiple geographic sites.
  • B. Hardware replacement initiates self-healing with minimal impact
  • C. Limiting the number of drives locally, which are not a part of the shared datastore.
  • D. Distributing data locally, not just across the hosts in HyperFlex cluster
  • E. Eliminating the need for additional hardware cards, while maintaining high performance.

Answer: BE

Explanation:
700-905 dumps exhibit

NEW QUESTION 15
Which three features for NVMe transfer protocol are valid? (Choose three.)

  • A. Uses PCIe interface
  • B. Streamlined commands for fewer CPU instructions
  • C. More and deeper queues
  • D. Requires 10 controller
  • E. Increases memory speed for more lOPs
  • F. Improves SAS and SATA speed

Answer: ABC

Explanation:
700-905 dumps exhibit

NEW QUESTION 16
When cabling a given HX node to the Fabric Interconnect which three actions are required? (Choose three.)

  • A. Connect the node to different port numbers on each of the two Fabric Interconnects.
  • B. Connect port 1 on the VIC to Fabric Interconnect A.
  • C. Connect server port L1 to Fabric Interconnect port L1.
  • D. Connect the node to the same port number on each of the two Fabric Interconnects.
  • E. Connect server port L2 to Fabric Interconnect port L2
  • F. Connect port 2 on the VIC to Interconnect B.

Answer: BDF

Explanation:
700-905 dumps exhibit

NEW QUESTION 17
Where is the VIC configuration for number type, identify, failover, settings, and bandwidth stored?

  • A. in non-volatile memory on the VIC
  • B. in UCS Manager service profiles
  • C. in VCenter virtual machine image
  • D. in UCS Manager server profiles

Answer: D

NEW QUESTION 18
How many PCIe standards-compliant interfaces do Cisco VICs support?

  • A. 512
  • B. 128
  • C. 256
  • D. 64

Answer: C

Explanation:
700-905 dumps exhibit

NEW QUESTION 19
How many DIMMs are supported per memory channel in the Cisco UCS M5 server?

  • A. 2
  • B. 1
  • C. 8
  • D. 4

Answer: A

Explanation:
700-905 dumps exhibit

NEW QUESTION 20
......

P.S. Surepassexam now are offering 100% pass ensure 700-905 dumps! All 700-905 exam questions have been updated with correct answers: https://www.surepassexam.com/700-905-exam-dumps.html (50 New Questions)